On-board artificial intelligence

Control that learns your home, night after night

Every installation is different: insulation, heat emitters, habits, climate. Rather than applying generic settings, synapsus continuously records its own operation and, every night, derives models suited to that particular home.

On the tabletThe models are computed on site, without Internet; only the weather forecasts come from the network. The data stays with you.
Learned every nightThe day's history enriches the models. The longer the installation runs, the more accurate they become.
CautiousThe AI only acts once its model is judged reliable. Until then, conventional control stays in charge.
Under control5 functions always active, 10 that the installer can enable. When disabled, a function keeps learning; its progress is displayed.
At the heart of the heat pump
Always active

Self-adapting expansion valve

The response of the refrigerant circuit is learned for each operating condition, for stable superheat and better efficiency.

Always active

Compressor speed

Three learned models, for speed, output and current, to reach the setpoint as precisely as possible, within the heat pump's limits.

Always active

Evaporator and condenser

Their speed is controlled on their temperature difference, with settings learned on the installation.

Comfort and anticipation
Can be enabled

Learned heating curves

For each zone, the tablet learns the curve that really maintains comfort, without overheating, and moves towards it by no more than 1 °C per week.

Can be enabled

Optimum start and stop

Heating and cooling: the tablet learns how each zone responds, sunshine included, and starts up to 2 hours earlier to be on time, or stops earlier when possible.

Can be enabled

Absence detection

Nobody home for 36 hours? The hot water switches to economy, with legionella protection kept, and the zones are lowered slightly. Everything returns to normal as soon as someone is back.

Can be enabled

Open window

A rapid drop in a room's temperature is recognised: the zone is switched off while the room is aired, for 30 minutes at most.

Energy and sunshine
Can be enabled

Hot water to suit your habits

Draw-offs are learned: hot water is ready when it is needed, heated preferably during off-peak hours, legionella protection included.

Can be enabled

Forecast solar thermal

Based on the weather forecast, the heat pump leaves to the sun what it is going to heat and only provides the top-up needed.

Can be enabled

Forecast photovoltaics

Production is learned according to the weather: the hot water or the pool is kept for the coming hours of surplus.

Maintenance and diagnosis
Can be enabled

Predictive maintenance

Every night, the past week is compared with the previous three months: fouling heat exchanger, falling water flow, possible refrigerant shortage, drifting outdoor sensor. The finding is logged and sent by e-mail.

Always active

Alarm diagnosis

As soon as a heat pump alarm occurs, the tablet suggests its probable cause in the log, based on the measurements and the installation's history.

Can be enabled

Fewer short cycles

If the compressor stops too quickly, the restart differential of the tanks widens automatically, for longer run times and a longer-lasting heat pump.

Help assistant

You type your question in your own words, "the house is cold", and the assistant opens the right help page. It works without Internet, in all 7 languages.

AI control screen
Each AI function and its learning status
Help assistant: question in everyday language
The assistant understands questions in everyday language
AI functions and model location
On-board model today, shared model tomorrow

The 15 functions are built into the tablet and tried out in demonstration; their on-site validation begins with the first installations. Learning can be reset function by function, and completely before delivery, with settings kept.

Example

The heating curve that really fits

A heating curve is usually set at commissioning, then adjusted in use, winter after winter. synapsus observes the temperature achieved in each zone every day and suggests the curve that maintains comfort without heating more than necessary.

  • Displayed next to the set curve: the difference can be seen at a glance.
  • Applied only if you choose: with a tap on "Apply", or gradually if the installer enables the function, by no more than 1 °C per week.
  • Always within limits: the minimum and maximum limits set by the installer are respected.
Heating curve and curve suggested by the AI
Set curve and curve suggested by the AI
Example

An expansion valve that learns its machine

Superheat is controlled by the opening of the electronic expansion valve. Each operating condition, depending on compressor speed and outdoor temperature, responds differently: synapsus learns these responses and, at every start-up, resumes the position and gains that worked the previous time.

  • Fast approach, fine holding: one gain to reach the setpoint, another to hold it.
  • Confirmed start-up: control waits until the pressure difference proves that the compressor is really running.
  • Refrigerant synoptic: pressures, temperatures, superheat, heat output and COP, current phase with the time remaining.
Refrigerant circuit synoptic diagram
The refrigerant circuit, live

AI working for the installer

Fewer adjustments after commissioning, more comfort and efficiency for the occupant.

Contact us